Integral cylinder
HSBB 200 – Technical Data
-
Type
Product Number
235195
Technical data
Energy efficiency class
B
Standby energy consumption/24 h at 65 °C
1,3 kWh
Nominal capacity, DHW cylinder
181 l
Surface, indirect coil
1,6 m²
Rated control voltage
230 V
Rated voltage, emergency/booster heater
400 V
Power consumption, emergency/booster heater
8,8 kW
Heat pump connection
22 mm
Heating circuit connection
22 mm
Cold water connection
G 1 A
DHW connection
22 mm
DHW circulation connection
G 1/2 A
Height
1328 mm
Width
694 mm
Depth
875 mm
Height of unit when tilted
1483 mm
Weight
150 kg
Suitable for
{WPL-A Premium, WPL 15 AC(S), WPL 07/09/13/17 ACS classic}
Installation Information:
Please ask your local power supply utility or a registered electrician to install appliances that are not fully wired, i.e. ready to plug in. The electrician should also be able to assist you with obtaining the agreement of the respective power supply utility required for the appliance installation.