Air source heat pumps
WPL-A 12 HK Plus compact duo Set 2 – Technical Data

  • Technical data

    Energy efficiency class, heat pump W35

    A++

    Energy efficiency class, heat pump W55

    A++

    Energy efficiency class, composite system (heat pump + controller) W35

    A++

    Energy efficiency class, composite system (heat pump + controller) W55

    A++

    Heating output at A7/W35 (EN 14511)

    8.66 kW

    Heating output at A2/W35 (EN 14511)

    8.10 kW

    Heating output at A-7/W35 (EN 14511)

    11.32 kW

    Max. cooling capacity at A35/W7

    14.88 kW

    Cooling capacity at A35/W18 partial load

    6.76 kW

    Max. cooling capacity at A35/W18

    17.06 kW

    COP at A7/W35 (EN 14511)

    4.61

    COP at A2/W35 (EN 14511)

    3.74

    COP at A-7/W35 (EN 14511)

    2.84

    Max. energy efficiency ratio at A35/W7

    2.38

    Energy efficiency ratio at A35/W18 partial load

    3.76

    Max. energy efficiency ratio at A35/W18

    2.83

    SCOP (EN 14825)

    4.05

    Sound power level (EN 12102)

    55 dB(A)

    Min./max. application limits for heat source

    -20/40 °C

    Max. application limit on the heating side

    65 °C

    Height

    1045 mm

    Width

    1490 mm

    Depth

    593 mm

    Weight

    175 kg

    Rated voltage, compressor

    400 V

    Rated voltage, emergency/auxiliary heater

    400 V

    Refrigerant

    R410A

    Further information about the set contents can be found under the respective product.

    Technical data and product variants

    For further details and product variants please refer to data sheet.

    Download as PDF